Home  »  Middle voltage power cables  »  2XSEY/ N2XSEY A2XSEY/ NA2XSEY

2XSEY/ N2XSEY A2XSEY/ NA2XSEY

Uo/U - 6/10 kV, 12/20 kV, 18/30kV IEC 60502-2 / DIN VDE 0276-620
The three-core cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution of electrical power with nominal voltage Uo/U 6/10; 12/20; 18/30 kV and frequency 50 Hz in urban and district electrical networks and for electrical supply of transformer's substations, small and medium industrial plants.
 
They are suitable for use in distribution installations, electric power stations and industrial systems.
The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduits and shafts, over shelves and grills directly underground in ditch and outdoor shelter
Cable construction
Construction
According to IEC 60502 and DIN VDE 0276-620
Conductor
Cu and Al stranded compacted, according to IEC 60228 class 2 and VDE 0295 class 2
Inner semi-conductive layer
semi-conductive XLPE compound
Insulation
XLPE compound
Outer semi-conductive layer
semi-conductive XLPE compound and semi-conductive tape or extruded semi-conductive XLPE compound
Metal screen
Cu wires concentrically laid and one contact of Cu tape with thickness of 0.1mm or Cu tapes laid with overlap over each phase
Cable assembly
Three insulated and screenesd phases are twisted with fillings and tape support
Inner sheatth
PVC compound
Sheath
PVC compound
type ST2 according to IEC 60502
type DMV 6 according to VDE
0276
Color
red
Technical data
Conductor resistance at 20°C
According to BDS904 (IEC60228) class 2
Operating temperature
90°C continuous operation
Overload temperature
130°C    /100h per year max./
Short circuit temperature
250°C /5 s max./
Nominal voltage Uo/U:
6/10;12/20 kV
Highest system voltage Uo/U, no more than
6/10; 12/20 kV
12kV; 24kV kV
Test voltage Uo/U
AC (≈) - 5 min
DC (=) - 15 min
6/10; 12/20 kV
15kV; 30kV kV
48kV; 96kV kV
Level of partial discharge
at 2*Uo
Bending radius, min
Temperature of laying
max. 5 pC
 
 
15x D cable
no less than - 20°C
Temperature of exploitation
-30 to 50°C
Tests
according to IEC 60502-2 or DIN VDE 0276-620
Force of strain in laying N max.
where:
Al cores - 30*n*S core Cu cores - 50*n*S core n- number of cores and -S-cross-section of conductors in mm
 
Construction data 2XSEY/N2XSEY, A2XSEY/NA2XSEY   6/10; 12/20; 18/30 kV
Number of conductors and nominal cross sec­tion
Thickness of insula­tion
Thickness
of
sheath
Nominal cross sec­tion of
screen
Cable diameter approx.
 
 
2XSEY,N2XSEY
A2XSEY,NA2XSEY
Mass of
Cu approx.
Mass of
cable
approx.
Mass of
Al approx.
Cable
Weight
approx.
Nxmm2
mm
mm
 mm2
mm
kg/km
kg/km
kg/km
kg/km
6/10 kV
 
 
 
 
 
 
 
 
3x35 rm /16
3x50 rm /16
3,4
34
2,5
2.5
16
16
46,4
48 8
1010 1363
2907
3408
298
404
2231
2497
3x70 rm /16
3,4
2,7
16
53,0
1968
4279
584
2965
3x95 rm /16
3,4
2,8
16
57,1
2732
5308
809
3481
3x120rm /16
3,4
2,9
16
60,3
3440
6195
1023
3899
3x150rm /25
3,4
3,0
25
64,2
4245
7383
1257
4545
3x185rm /25 3x240rm /25
3,4
34
3,2
3,4
25
25
68,5
74,3
5311 6981
8741
10817
1579
2071
5195
6153
3x300rm /25
3,4
3,5
25
79,6
8661
12906
2589
7138
12/20kV
3x35 rm /16
 
5,5
 
2,8
 
16
 
56,7
 
1010
 
3793
 
298
 
3117
3x50 rm /16
5,5
2,9
16
59,3
1363
4345
404
3434
3x70 rm /16
5,5
3,0
16
63,3
1968
5248
584
3934
3x95 rm /16 3x120rm /16
5,5
5.5
3,1
3,2
16
16
67,4
2732
6331
7275
809
1023
4504
4979
70,6
3440
3x150rm /25
5,5
3,4
25
74,7
4245
8566
1257
5728
3x185rm /25
5,5
3,5
25
78,8
5311
9968
1579
6422
3x240rm /25
5,5
3,7
25
84,5
6981
12155
2071
7491
 
 
 
 
 
 
 
 
 
18/30 kV
3x50 rm /16
 
8
 
3,3
 
16
 
71,7
 
1363
 
5624
 
404
 
4713
3x70 rm /16
3x95 rm /16
8
8
3,4
3,5
16
16
75,8
79,8
1968 2732
6610
7791
584
809
5296
5964
3x120rm /16
8
3,7
16
83,3
3440
8819
1023
6523
3x150rm /25
8
3,8
25
87,1
4245
10185
1257
7347