2XSE2Y / N2XSE2Y A2XSE2Y / NA2XSE2Y

Uo/U - 6/10 kV, 12/20 kV, 18/30kV IEC 60502-2 / DIN VDE 0276-620
The three-core cables with insulation of cross-linked polyethylene (XLPE) are designed for transfer and distribution of electrical power with nominal voltage Uo/U 6/10; 12/20; 18/30 kV and frequency 50 Hz in urban and district electrical networks and for electrical supply of transformer's substations, small and medium industrial plants.
 
They are suitable for use in distribution installations, electric power stations and industrial systems. 
The cables are for fixed assembly in lines with unlimited difference levels, indoor installations, in cable ducts, conduits and shafts, over shelves and grills directly underground in ditch and outdoor shelter.
 
 
 
Cable construction
Construction
According to IEC 60502 and DIN VDE 0276-620
Conductor
Cu and Al stranded compacted, according to IEC 60228 class 2 and VDE 0295 class 2
Inner semi-conductive layer
semi-conductive XLPE compound
Insulation
XLPE compound
Outer semi-conductive layer
semi-conductive XLPE compound and semi-conductive tape or extruded semi-conductive XLPE compound
Metal screen
Cu wires concentrically laid and one contact of Cu tape with thickness of 0.1mm or Cu tapes laid with overlap over each phase
Cable assembly
Three insulated and screenesd phases are twisted with fillings and tape support
Inner sheatth
PVC compound
Sheath
PE compound
type ST7 according to IEC 60502
type DMP 2 according to VDE
0276
Color
Black
Technical data
Conductor resistance at 20°C
According to BDS904
(IEC60228) class 2
Operating temperature
90°C continuous operation
Overload temperature
130°C /100h per year max./
Short circuit temperature
250°C /5 s max./
Nominal voltage Uo/U:
6/10;12/20 kV
Highest system voltage
6/10; 12/20 kV
Uo/U, no more than
12kV; 24kV kV
Test voltage Uo/U
6/10; 12/20 kV
AC () - 5 min
15kV; 30kV kV
DC (=) - 15 min
48kV; 96kV kV
Level of partial dischargeat 2*Uo
 max. 5 pC
Bending radius, min
15x D cable
Temperature of laying
no less than - 20°C
Temperature of
exploitation
 -30 to 50°C
 Tests
according to IEC 60502-2 or DIN VDE 0276-620
Force of strain in laying N where:
 
 
Al cores - 30*n*S core Cu cores - 50*n*S core
n- number of cores and -S-cross-section of conductors in mm
 
Construction data 2XSE2Y/N2XSE2Y, A2XSE2Y/NA2XSE2Y 6/10; 12/20; 18/30 kV
Number of conductors and nominal cross sec­tion
Thickness of insula­tion
Thickness
of
sheath
Nominal cross sec­tion of screen
Cable diameter approx.
2XSE2Y,
N2XSE2Y
A2XSE2Y,
NA2XSE2Y
Mass of
Cu approx.
Mass of
cable
approx.
Mass of
Al approx.
Mass of
cable
approx.
Nxmm2
mm
mm
mm2
mm
kg/km
kg/km
kg/km
kg/km
6/10 kV
 
 
 
 
 
 
 
 
3x35 rm /16
3x50 rm /16
3,4
3,4
2,5
2,5
16
16
46,4
48,8
1010 1363
2849
3348
298
404
2174
2437
3x70 rm /16
3,4
2,7
16
53,0
1968
4208
584
2894
3x95 rm /16
3,4
2,8
16
57,1
2732
5229
809
3402
3x120 rm /16
3,4
2,9
16
60,3
3440
6108
1023
3812
3x150rm /25
3,4
3,0
25
64,2
4245
7287
1257
4449
3x185 rm /25
3x240 rm /25
3,4
3,4
3,2
3,4
25
25
68,5
74,3
5311 6981
8632
10690
1579
2071
5086
6027
3x300 rm /25
3,4
3,5
25
79,6
8661
12766
2589
6999
                 
12/20 kV
3x35 rm /16
 
5,5
 
2,8
 
16
 
56,7
 
1010
 
3714
 
298
 
3038
3x50 rm /16
3x70 rm /16
5,5
5,5
2,9
3,0
16
16
59,3
63,3
1363 1968
4259
5153
404
584
3349
3839
3x95 rm /16
3x120 rm /16
5,5
5,5
3,1
3,2
16
16
67,4
70,6
2732 3440
6226
7162
809
1023
4399
4866
3x150rm /25
5,5
3,4
25
74,7
4245
8439
1257
5601
3x185 rm /25
5,5
3,5
25
78,8
5311
9830
1579
6284
3x240 rm /25
5,5
3,7
25
84,5
6981
11998
2071
7334
 
 
 
 
 
 
 
 
 
18/30 kV
3x50 rm /16
 
8,0

3,3
 
16
 
71,7
 
1363
 
5505
 
404
 
4596
3x70 rm /16
8,0
3,4
16
75,8
1968
6480
584
5167
3x95 rm /16
8,0
3,5
16
79,8
2732
7651
809
5824
3x120 rm /16
8,0
3,7
16
83,3
3440
8665
1023
6369
3x150rm /25
8,0
3,8
25
87,1
4245
10019
1257
7181