(N)HXH-FE 180

Uo/U - 0.6/1 kV DIN VDE 0266
The power cables with retaimnent of insulation 180 min. flame retardant, with low halogen free smoke emission and corrosion at fire conditions are suitable for used in electrical installations for break-downsupply, signalization and control in:
 
important objects - power stations (nuclear, thermal), transformer substations, metro, airport public buildings - hospitals, hotels, theaters, cinemas,public and commercial centers, places with great concentration of people and material values whose safety in case of fire should be guaranteed.

The cables are designed for fixed laying in dry and wet premises and outdoor, but not directly underground or in water. Laying in cable duct is allowed in case precautions are taken no water collection in the duct to be guaranteed.
 
 
Cable construction
Construction
According to VDE 0266
Conductor
Cu wires according to VDE 0295 (HD 383) cl.1 or 2 (IEC 60228)
Insulation
double layer insulation consist ing of mica tape and cross-linked polymer according to VDE 0207 part 23 HI1
Inner sheath
tapes or extruded layer
Sheath
plastic compound, type HM4 according to VDE 0207 part.24
Color
orange
Technical data
Conductor resistance at 20°C
according to VDE 0295 (IEC60228) cl.1 or 2
Operating temperature
90°C continuous operation
Short circuit temperature
250°C / 5 s max./
Nominal voltage Uo/U: Test voltage
0.6/1 kV
AC - 4kV
Bending radius, min
15xD cable
Tests
according to DIN VDE 0266part 3 and IEC 331
Retainment of insulation according to IEC 331
180 min
Temperature range
-30 to +70°C
Color coding
Single core Double core
- black or yellow-green - blue and - brown or yellow-green and black

 3 -core
4 - core
5 - core
Multiple core
brown;
black;
grey
or
yellow/gre
en; blue;
 
brown
blue; brown;
black
grey;
or
yellow/green;
brown
black; grey
blue;
brown;black
grey; black
or
yellow/green;
blue; brown;
black; grey
black with number
mark on cores
or
black with number
mark on cores and
yellow/green core
in the outer cover
Construction data (N)HXH FE 180 0.6/1 kV
Number of conductors and nominal cross section
Cable diameter approx.
Mass of
Cu approx.
Mass of cable approx.
Nxmm2
mm
kg/km
kg/km 
1x4,0re
8
37
105
1x6,0re
9
56
130
1x10 0re
10
94
170
1x16
11
149
250
2x1.5re 12 28 190
2x2,5re
13
46
220
2x4,Ore 14 75 200
2x6,Ore
15
112
340
2x10,0re
 16
 188
 450
3x1.5re 15 43 240
3x2,5re
16
70
290
3x4,0re 17 112 340
3x6, 0re
18
168
450
3x10re 20 282 620
3x16rm
22
460
850
3x25rm 26 728 1300
4x1,5re
15
57
280
4x2.5re 16 93 350
4x4, 0re
17
149
440
4x10re
20
376
760
4x16rm 22 614 1100
4x25rm
26
970
1600
4x35 29 1346 1940
4x50rm
33
1817
2570
5x1,5re
17
71
330
5x4,0re
20
187
520
5x6,0re 22 279 660
5x10re
24
470
950
5x16rm
27
767
 1300
7x1.5re 19 100 380
12x1,5re
23
171
580